BRAND | Stahl |
Product | P/N: 132644, Type: 8082/1-2-10 |
Description | contact element |
Internal code | IMP4983314 |
Custom code | 85365080 |
Technical specification | Rated operating voltage AC: 0 V | Rated operating current at AC: 0.000 A | Rated operating voltage DC: 0 V | Rated operating current at DC: 0.000 A | Number of contacts: 1 | Connection type: screw terminal |... 2.5 mm2 flexible | Housing material: polyamide | Contact material: gold-plated | Range of application (zones): 1, 2 | Ambient temperature min.: -60 °C | Ambient temperature max.: +70 °C | Gas explosion protection: II 2 G Ex db eb IIC Gb | Blow weather protection: I M2 Ex db eb I Mb |
Discover the superior quality and performance of the Stahl P/N: 132644, Type: 8082/1-2-10 with Impexron GMBH in Sweden (Sverige) . Whether you are looking for reliability or efficiency, this product meets all your industrial needs.
The P/N: 132644, Type: 8082/1-2-10 is designed to provide optimal performance and durability in various applications. Known for its high-quality construction and innovative features, it is a preferred choice for professionals.
Key Features of P/N: 132644, Type: 8082/1-2-10 :
At Impexron GMBH , we offer the P/N: 132644, Type: 8082/1-2-10 at competitive prices and with the fastest delivery times across Sweden (Sverige) . Our expert team is ready to assist you with all your inquiries and provide tailored solutions to meet your specific needs.
Why Choose Impexron GMBH ?
Get Your Quote Today! Ready to enhance your operations with the P/N: 132644, Type: 8082/1-2-10 ? Contact us now for a personalized quote. Fill out the form below or send us an email with your inquiry. Let us help you make a cost-effective, quality-driven choice for your business.
Important Notice: While we supply Stahl products, Impexron GMBH is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
P/N: 150494, Type: 8570/11-506
Switch socket
3X16 A EX PROOF PLUG
plug
Plug explosion-proof
(Plug explosion Proof Type: 8570 / 12-406 Bemessungsbetr.spg. / Frequency: 380-415 V 50/60 Hz Operating current: 16 A Detailed Contacts 4 P (3 P + PE) Color code: red Coding (time position): 6 Housing material: Polyamide Field of Application (zones): 1, 2, 21, 22 Gas explosion protection: II 2 G Ex de IIC T6 Dust explosion protection: II 2 D IP66 80 ° C Ambient temperature min. : -30 ° C Ambient temperature max. +55 ° C Protection (IP): IP66 Terminals: 1.5 mm Cable entry: 8 ... 20 mm plug explosion proof)
P/N: 150854, Type: 8571/11-506
switch socket
PLUG,UTILITY, 2-POLES
p/n: 270900, Type: 8579/31-506
Switch socket for low temperature, explosion-proof
Pushbutton
(Button label Label marking : STOP Colour of label : red For further information, see : www.r-stahl.com Web code 8082A)
(Rotary handle, small lockable explosion-protected Enclosure material : Polyamide Seal : Standard Mounting : with threaded Switching function : latching Number of switching positions : 2 Construction type : vertical Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex e II Dust explosion protection : II 2 D Ex tD A21 Min. ambient temperature : -50 °C Max. ambient temperature : +70 °C Type of protection (IP) : IP66 For further information, see : www.r-stahl.com Web code 8082A)
8703-PUSH BUTTON ASSEMBLY (OBSOLETE REPLACED BY 8602)
PUSH BUTTON FOR START-NO CONTACT
Single-channel safety barriers explosion-protected
9118/11-11-10 - OBSOLETE (REPLACED BY 9118/11-11-10)
ics modul-mA isolating repeater(max vol.:8.7 V max. cur.:0.4 mA max. pow.:11mW power supp.:24 vDC)
Barrier
BARRIER: PROTECTIVE, for receiving and transmitting UNIFIED SIGNALs POWER SUPPLY SENSOR, EEX IA IIC
mA-Trennübertrager
iSPAC separation transformer
Isolator analog output
BARRIER: PROTECTIVE, for receiving and transmitting UNIFIED SIGNALs
(ISpac Switching amplifier Field Circuit Ex i explosion-protected Type : 9170/10-12-21s Max. Voltage Uo : 10,6 V Max. Current Io : 24 mA Max. Demand Po : 64 mW Min. nominal voltage : 120 V Max. nominal voltage : 230 V Nominal current : 12 mA Number of channels : 1 Output / channel : 1 change over contact LFD relay : Yes Line fault transparency : No Min. ambient temperature : -20 °C Max. ambient temperature : +70 °C Gas explosion protection : II (1) G [Ex ia] IIC Dust explosion protection : II (1) D [Ex ia] IIIC)
160293, IS PACIsolating RepeaterSwitching RepeaterField Circuit Ex iexplosion-protectedType : 9170/20-12-11sMax. Voltage Uo : 10,6 VMax. Current Io : 48 mAMax. Demand Po : 128 mWNominal voltage : 24 V DCNominal current : 33 mA Number of channels : 2Output / channel : 1 change over contactLFD relay : YesLine fault transparency : NoMin. ambient temperature : -20 °CMax. ambient temperature : +70 °CDust explosion protection : II (1) D [Ex ia] IIICFor further information, see : www.r-stahl.com Web code 9170ASwitching Repeater Series 9170, Field Circuit Ex i, dual channelBasic function: binary / digital inputIntrinsically safe input: [Ex ia] IICPower supply: 24 V DCInput: acc. to EN 60947-5-6 (NAMUR)Output / channel: 1 change-over contactConnection type: Screw terminals
(Binary output loop-powered IS pac)
temperature transmitter
FIELDBUS ISOLATING REPEATER