Technical specification NITROGEN GAS FLOW MEASUREMENT. FLOW AND PROCESS FLUID SPECIFICATIONS: NITROGEN GAS, 38ºC, SPECIFIC GRAVITY: 0.967. INLET PRESSURE 213.35 PSIG (15 KG/CM2), PIPE DIAMETER: 3". VOLUMETRIC FLOW: MINIMUM: 240 NM3/H (141.3 SCFM), NOMINAL: 960 NM3/H (565.03 SCFM), MAXIMUM: 1,200 NM3/H (706.29 SCFM). POWER SUPPLY: 24 VDC (LOOP POWERED). THE TRANSMITTER MUST INCLUDE PRESSURE AND TEMPERATURE SENSORS IN INTEGRAL FORM FOR MASS FLOW MEASUREMENT, ANALOG OUTPUT: ACTIVE/PASSIVE (SELECTABLE) 4-20 MA, WITH HART PROTOCOL. HOUSING FOR METER AND TRANSMITTER: NEMA 4X ALUMINUM, INCLUDES DISPLAY FOR LOCAL INDICATION. CONNECTION TO PROCESS: FLANGED 300# ANSI B16.5. INPUTS FOR ELECTRICAL CONNECTIONS: 1/2" NPT. ACCURACY: +/- 0.5%, REPEATABILITY: +/- 0.1%, FM CLASS I DIV I APPROVAL.

Please send us your request per e-mail, so we can send you our offer with competitive prices and delivery time for Foxboro - 84CF020-TPRF2STSTJFD number or any other model you need. We can offer competitive price, and delivery time with wide products distribution network in Sweden (Sverige) Industrial products Market.